The MX 62 modular controller systemis a versatile and easily installable gas and flame detection solution for hydrocarbon applications.
The MX 62 system meets the requirements of ATEX 100 A and offers the high level of security required by SK2 and SIL3-rated systems.
Cost-effective and secure installation
The structure of the MX 62 system has been developed to provide redundancy. Reliable data is passed quickly from the detectors to the relays.
Structured programming
The ConfigPro.exe software configures the MX 62 through a secure, password protected interface.
Saves space and optimises cost
- Innovative design meets the new safety requirements
- Modularity allows a personalised operation and custom wiring
- Flexibility allows better integration with your system
- High reliability ensures minimum maintenance
- Programmable outputs reduce relay requirements
Various Modules:
LED Module (A)
16 channels (eight channels standard)
- Four alarm thresholds
- Reset / acknowledge
- Power ‘on’
- Fault
LCD Module (B)
Up to 30 displays can be networked with the MX 62, allowing anywhere / anytime measurement display
- Graphic, alphanumeric, high-definition LCD
- User-friendly display graphics
- Data storage: (optional five days)
- Can be remote via RS 485
Printer Module (C)
- Printing alarms, relay operating status, fault, minimum / maximum average over eight hours
- Type ASCII, alphanumeric 40 or 80 characters
- Parallel connection
CPU Module (D)
The CPU module is the heart of the system, with backup power supply and two processors.
Plug in the LED and LCD modules, or remote connection via RS485 (four wires plus shield).
- Centralised management
- Connection to different modules
- Connection to an internal or external printer
Analogue Input Module (E)
Analogue signals from the detectors to be input into the control system. Dual converters ensure reliable and redundant operation.
- Direct connection with the MX 62 system or remote via the adapter module
- Up to eight measurement points, two or three wire
Adapter Module (F)
- Allows three operating modes
- Up to 16 addressable detectors in a loop configuration
- Up to eight addressable detectors combined with a remote analogue module
- Connection of two analogue input modules
- The module can be remote via two RS485 networks (two x four wires plus screened system)
Relay Module (G)
- Fitted with two processors linked with the CPU
- Principal module: eight relays
- Extension module: eight relays
- NO / NC contacts
- Breaking capacity: 460 VA, 60 W
- Positive safety individually programmable
- The module can be remote via two RS485 (two x four wires plus screened system)
Analogue Output Module (H)
- Fitted with two processors linked with the CPU
- Fitted with eight analogue 4mA-20mA or 0V-10V outputs
- Each output is programmed to transmit:
- The real-time value for one each input
- The linearised value
- Means or max for a detector group
- Mimic module: open collector (56) suitable to drive LED mimic panel as per MX 62 channel
Communication Module (I)
- Link to a supervisor for data exportation (PLC, DCS or SCADA)
- Link with CPU via the RS 232
- Personalised or Modbus protocol via RS 422
Optional communication splitter modules are available.